HIGHFIL Gas Turbine Air Intake Filter Specification
Of
2x120 MW PPP, Model: GE, PG-9171-E
Primary Filter (Class- G4)
Item No
|
Name of Item or Related Service
|
Required Technical Specifications and Standards
|
Manufacturer’s guaranteed specification
|
1
|
Primary Air Intake Filter
|
Model No
|
To be mentioned
|
|
Manufacturer’s Name
|
To be mentioned
|
|
Country of Origin
|
To be mentioned
|
|
Size
|
592mm × 592mm × 360mm
|
|
No. of Pocket per Filter
|
6 nos.
|
|
Filter media & Grade
|
G4, Synthetic Fiber, non-woven, Washable
|
|
Pocket
|
Controlled media spacing method V-shaped pockets
|
|
Frame
|
Galvanized Metal
|
|
Air flow M3/hr
|
4250
|
|
Initial Pressure drop
|
Maximum 45Pa (4.588 mm Wc)
|
|
Final pressure drop
|
Minimum 250 Pa (25.49 mm Wc)
|
|
Average Arrestance
|
Minimum 91% at 250 Pa
|
|
ASHRAE Dust Holding Capacity
|
Dust Holding Capacity minimum 495 grams on ASHRAE 52/76 AT 250 Pa rated air flow
|
|
Initial Arrestance
|
Minimum 79%
|
|
Media Area
|
Minimum 2.6 m2
|
|
Weight
|
1.8 - 2.2 Kg
|
|
Uniform Media Spacing
|
High Cap Pocket should be separately manufactured.
|
|
Coalescing Characteristics
|
Very Good Coalescing Characteristics
|
|
Bag Type
|
Self-Supported bags. Each Pocket should self-supported.
|
|
Gas Turbine Air Intake Filter Specification
Of
2x120 MW PPP
Secondary Filter (Class-F8)
Item No
|
Name of Item or Related Service
|
Required Technical Specifications and Standards
|
Manufacturer’s guaranteed specification
|
1
|
Secondary Air Intake Filter
|
Model No
|
To be mentioned
|
|
Manufacturer’s Name
|
To be mentioned
|
|
Country of Origin
|
To be mentioned
|
|
Size
|
592 × 592 × (290-300*) Filter depth can be 290 to 300 mm
|
|
Type
|
High efficiency water resistant Secondary Cartridge Type Air Filter (V Pack Mini Pleat Filter Element)
|
|
Filter Media
|
Glass fiber/Synthetic
|
|
Each Cartridge Weight
|
7.00-8.50 Kg
|
|
Filter Frame
|
Polypropylene/ Polystyrene
|
|
Element Construction
|
Double & Vertical pleated
|
|
Seal & Gasket
|
Polyurethane/Continuous modulated PU foam, Open hot melt separator design
|
|
Temperature limit
|
Minimum 45 deg C
|
|
Rated air Flow
|
4250 CMH
|
|
Initial resistance at rated air flow
|
(130-170) Pa
|
|
Final resistance at rated air flow/Final DP
|
Minimum 600 pa at rated air flow
|
|
Dust holding capacity at final resistance on ASHRAE TEST DUST
|
Minimum 596 grms
|
|
Average efficiency of 0.4μm Particles (%)
|
Minimum 90%
|
|
Media Area
|
Minimum 18.2 m2
|
|
Bursting Pressure
|
Greater than 3500 Pa
|
|
Outside Protection
|
The filter media should be protected by non-metallic aerodynamic grid which will be added to air exit (Plastic faceguards on air leaving side).
|
|